High Airflow at Low to Medium Pressure
Optimized for delivering large volumes of air efficiently in applications requiring moderate static pressure.

Energy-Efficient Performance
Equipped with reliable motors that reduce energy consumption and operating costs.

Quiet and Smooth Operation
Forward curved blade design minimizes noise and vibration for comfortable environments.

Durable and Reliable Construction
Built from quality materials to ensure long service life and consistent performance.

Customizable Configurations
Available in various sizes and motor options, with flexible mounting and housing to meet diverse requirements.

Easy Installation and Maintenance
Compact design allows for straightforward installation and hassle-free upkeep.

Versatile Application Range
Suitable for HVAC systems, air handling units, ventilation, heating, and light industrial uses.
- Forward Curved Centrifugal Fan
133mm High Airflow Capacity EC Dual-inlet Forward Curved Cen...Dual-inlet forward curved centrifugal fans provide a combination of high airflow...
Read More
133mm High Airflow Capacity Dual-inlet Forward Curved Centri...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
180mm Energy Efficient Forward Curved Centrifugal Fan For HV...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
160mm Energy Efficient Forward Curved Centrifugal Fan For Ve...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
150mm Energy Efficient Forward Curved Centrifugal Fan For Fa...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
140mm Energy Efficient Forward Curved Centrifugal Fan For Ve...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
133mm Energy Efficient Forward Curved Centrifugal Fan For Ve...Belmont AC forward curved centrifugal fans are designed for high airflow in low-...
Read More
HVAC SystemsEfficient air distribution and ventilation for residential and commercial heating and cooling.
Air Handling Units (AHUs)Smooth airflow delivery in air treatment and circulation equipment.
Clean RoomsMaintaining controlled, contaminant-free environments in pharmaceutical and electronics manufacturing.
Ventilation SystemsProviding reliable fresh air intake and exhaust in various industrial settings.
Heating EquipmentEnhancing heat transfer and air circulation in furnaces and boilers.
Light Industrial CoolingCooling machinery and workspaces in manufacturing and assembly lines.
Product Catalog for Forward Curved Centrifugal Fans
| Fan Model | Motor Type | Size (mm) | Fan Size (W×H×D) | Supply | Voltage (V) | Frequency (Hz) | Power Input (W) | Max airflow (m³/h) | Noise (dBA) | IP class |
| BMF(K)2E160-GQ | AC | 160 | 185×185×100 | 1P,220~240V | 230 | 50 | 280 | 610 | 72 | IP54 |
| BMF(K)4E160-GQ | AC | 160 | 175×175×90 | 1P,220~240V | 230 | 50/60 | 67/85 | 400/430 | 65 | IP54 |
| BMF(K)4E180-GQ | AC | 180 | 180×180×115 | 1P,220~240V | 230 | 50/60 | 125/150 | 650/600 | 60 | IP54 |
| BMF(K)4D200-GQ | AC | 200 | 240×240×158 | 3P,360~440V | 400 | 50 | 330 | 1250 | 75 | IP54 |
| BMF(K)4E200-GQ | AC | 200 | 240×240×158 | 1P,220~240V | 230 | 50 | 330 | 1230 | 75 | IP54 |
| BMF(K)4E200-GQ06-LD | AC | 200 | 240×240×165 | 1P,220~240V | 230 | 50 | 250 | 1075 | 75 | IP54 |
| BMF(K)4E200-GQ10-LD | AC | 200 | 240×240×140 | 1P,220~240V | 230 | 50 | 270/200 | 1080/810 | 75 | IP54 |
| BMF(K)4D225-GQ | AC | 225 | 265×265×183 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 490 | 1770 | 80 | IP54 |
| BMF(K)4E225-GQ | AC | 225 | 265×265×183 | 1P,220~240V | 230 | 50 | 510 | 1800 | 80 | IP54 |
| BMF(K)4E225-GQ01 | AC | 225 | 265×265×185 | 1P,220~240V | 230 | 50 | 510 | 1800 | 80 | IP54 |
| BMF(K)4E225-GQ08-LD | AC | 225 | 265×265×180 | 1P,220~240V | 230 | 50 | 330 | 1243@80 | 78 | IP54 |
| BMF(K)4E225-GQ10-LD | AC | 225 | 265×265×140 | 1P,220~240V | 230 | 50 | 510/290 | 1660/1070 | 78 | IP54 |
| BMF(K)6D225-GQ | AC | 225 | 265×265×183 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 300 | 1300 | 72 | IP54 |
| BMF(K)6E225-GQ | AC | 225 | 265×265×183 | 1P,220~240V | 230 | 50 | 250 | 1300 | 72 | IP54 |
| BMF(K)4D250-GQ | AC | 250 | 300×300×195 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 870 | 2500 | 84 | IP54 |
| BMF(K)4E250-GQ | AC | 250 | 300×300×195 | 1P,220~240V | 230 | 50 | 900 | 2500 | 83 | IP54 |
| BMF(K)4E250-GQ13-LD | AC | 250 | 300×300×200 | 1P,220~240V | 230 | 50 | 510 | 1925@80 | 81 | IP54 |
| BMF(K)4E250-GQ14-LD | AC | 250 | 300×300×210 | 1P,220~240V | 230 | 50 | 720/430 | 2200 | 81 | IP54 |
| BMF(K)6D250-GQ | AC | 250 | 300×300×195 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 320 | 1700 | 73 | IP54 |
| BMF(K)4D280-GQ | AC | 280 | 338×338×238 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 1700 | 3500 | 85 | IP54 |
| BMF(K)4E280-GQ | AC | 280 | 338×338×238 | 1P,220~240V | 230 | 50 | 1600 | 3500 | 85 | IP54 |
| BMF(K)4E280-GQ11-LD | AC | 280 | 340×340×220 | 1P,220~240V | 230 | 50 | 900 | 2711@160 | 83 | IP54 |
| BMF(K)4E280-GQ12-LD | AC | 280 | 330×330×170 | 1P,220~240V | 230 | 50 | 1300/1080 | 3080/2680 | 83 | IP54 |
| BMF(K)6D280-GQ | AC | 280 | 338×338×238 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 450 | 2200 | 74 | IP54 |
| BMF(K)6E280-GQ | AC | 280 | 338×338×238 | 1P,220~240V | 230 | 50 | 450 | 2250 | 74 | IP54 |
| BMF(K)4D315-GQ | AC | 315 | 375×375×248 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 2200 | 4000@420 | 87 | IP54 |
| BMF(K)4E315-GQ | AC | 315 | 375×375×248 | 1P,220~240V | 230 | 50 | 2300 | 4000@450 | 87 | IP54 |
| BMF(K)6D315-GQ | AC | 315 | 375×375×248 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 780 | 3200@100 | 77 | IP54 |
| BMF(K)6E315-GQ | AC | 315 | 375×375×248 | 1P,220~240V | 230 | 50 | 720 | 2800@150 | 77 | IP54 |
| BMF(K)4D355-GQ | AC | 355 | 413×413×287 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 3500 | 6000@500 | 92 | IP54 |
| BMF(K)6D355-GQ | AC | 355 | 413×413×270 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 1150 | 4100@200 | 80 | IP54 |
| BMF(K)8D355-GQ-LD | AC | 355 | 415×415×280 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 660 | 3580 | 68 | IP54 |
| BMF(K)4D400-GQ | AC | 400 | 455×455×309 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 4800 | 6000@750 | 84 | IP54 |
| BMF(K)4D400-GQ04-LD | AC | 400 | 455×455×310 | 3P,396~484V | 440 | 60 | 4800 | 5900@950 | 81 | IP54 |
| BMF(K)6D400-GQ | AC | 400 | 455×455×279 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 2800 | 7000@50 | 86 | IP54 |
| BMF(K)8D400-GQ | AC | 400 | 455×455×279 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 1700 | 5800 | 76 | IP54 |
| BMF(K)6D450-GQ | AC | 450 | 540×540×337 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 3500 | 7500@450 | 87 | IP54 |
| BMF(K)8D450-GQ | AC | 450 | 540×540×337 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 2000 | 7200@180 | 80 | IP54 |
| BMF(K)6D500-GQ | AC | 500 | 570×570×315 | 3P,380~440V | 400 | 50 | 4400 | 9150@600 | 84 | IP54 |
| BMF(K)2E120-GQ-R | AC | 120 | 117×188×159 | 1P,220~240V | 230 | 50/60 | 60/90 | 170/175 | 62 | IP54 |
| BEF(K)6E133-PGWSAV0 | EC | 133 | 254×200×176 | 1P,200~277V | 230 | 50/60 | 130 | 780 | 65 | IP54 |
| BMF(K)2E133-GQ-R | AC | 133 | 115×181×175 | 1P,220~240V | 230 | 50/60 | 90/103 | 300 | 65 | IP54 |
| BMF(K)2E150-GQ-R | AC | 150 | 130×210×210 | 1P,220~240V | 230 | 50/60 | 180/210 | 510 | 70 | IP54 |
| BMF(K)2E160-GQ-R | AC | 160 | 245×130×220 | 1P,220~240V | 230 | 50 | 280 | 610 | 72 | IP54 |
| BMF(K)4E160-GQ-R | AC | 160 | 130×250×220 | 1P,220~240V | 230 | 50/60 | 67/85 | 400 | 65 | IP54 |
| BMF(K)2E180-GQ-R | AC | 180 | 170×280×260 | 1P,220~240V | 230 | 50 | 280 | 640@200 | 65 | IP54 |
| BMF(K)4E180-GQ-R | AC | 180 | 170×280×260 | 1P,220~240V | 230 | 50/60 | 125/150 | 650/600 | 60 | IP54 |
| BMF(K)4D200-GQ-R | AC | 200 | 190×435×367 | 3P,360~440V | 400 | 50 | 330 | 1250 | 77 | IP54 |
| BMF(K)4E200-GQ-R | AC | 200 | 190×435×367 | 1P,220~240V | 230 | 50 | 330 | 1250 | 77 | IP54 |
| BMF(K)4D225-GQ-R | AC | 225 | 211×482×405 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 490 | 1750 | 80 | IP54 |
| BMF(K)4E225-GQ-R | AC | 225 | 211×482×405 | 1P,220~240V | 230 | 50 | 510 | 1800 | 80 | IP54 |
| BMF(K)6E225-GQ-R | AC | 225 | 211×482×405 | 1P,220~240V | 230 | 50 | 250 | 1300 | 72 | IP54 |
| BMF(K)4D250-GQ-R | AC | 250 | 232×518×440 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 870 | 2500 | 84 | IP54 |
| BMF(K)4E250-GQ-R | AC | 250 | 232×518×440 | 1P,220~240V | 230 | 50 | 900 | 2400 | 83 | IP54 |
| BMF(K)6E250-GQ-R | AC | 250 | 232×518×440 | 1P,220~240V | 230 | 50 | 320 | 1650 | 73 | IP54 |
| BMF(K)4D280-GQ-R | AC | 280 | 262×577×485 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 1700 | 3500 | 85 | IP54 |
| BMF(K)4E280-GQ10-LDR | AC | 280 | 180×480×415 | 1P,220~240V | 230 | 50 | 690 | 2100@350 | 75 | IP54 |
| BMF(K)6D280-GQ-R | AC | 280 | 262×577×485 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 450 | 2400 | 74 | IP54 |
| BMF(K)4D315-GQ-R | AC | 315 | 280×638×536 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 2200 | 4000@420 | 87 | IP54 |
| BMF(K)6D315-GQ-R | AC | 315 | 280×638×536 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 780 | 2700@150 | 77 | IP54 |
| BMF(K)4D355-GQ-R | AC | 355 | 305×695×600 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 3500 | 4500@750 | 92 | IP54 |
| BMF(K)6D355-GQ-R | AC | 355 | 305×695×600 | 3P,200~240/380~440V △/Y | 230/400 | 50 | 1150 | 4100@200 | 80 | IP54 |
FAQs of Belmont Forward Curved Centrifugal Fans
- Q: What applications are forward curved centrifugal fans best suited for?A: They are ideal for HVAC systems, air handling units, clean rooms, ventilation, heating equipment, and light industrial cooling.
- A: Forward curved fans deliver higher airflow at lower static pressure, while backward curved fans handle higher static pressure more efficiently with less energy consumption.
- Q: Can these fans be customized?A: Yes, Belmont offers customizable sizes, motor types, mounting options, and materials to meet specific customer requirements.
- Q: What types of motors are available for these fans?A: Both AC and EC motor options are available, providing flexibility depending on energy efficiency and application needs.
- Q: How quiet are forward curved centrifugal fans during operation?A: They are designed for smooth, low-noise operation, making them suitable for environments requiring quiet airflow.
- Q: What maintenance is required for these fans?A: Routine cleaning and periodic inspections are recommended to ensure optimal performance and longevity.
- Q: Are these fans compliant with international standards?A: Yes, Belmont fans comply with CE, RoHS,UL, and other relevant certifications to guarantee quality and safety.