AC Axial Fan BMF300
1.The features of Axial Flow Fan are Low depth installation, low noise and high efficiency, which is especially suitable for air flow in heat exchangers.
2.Applications: Ventilation, air conditioning and refrigeration, wind power and mechanical engineering, industry of refined processing equipment.
3.Customized manufacturing available
[wpforms id="3485"]
Product description
Specifications
Axial fan - AC - 300
Size (mm) | Supply | Poles | Voltage(V) | Frequency(Hz) | Power Input(W) | Current(A) | Max airflow(m³/h) | Speed(rpm) | Noise(dBA) | Amb.temp.perm.(℃) | Mass(kg) | Insulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|
300 | 1P,220~240V | 2 | 220 | 60 | 270 | 1.2 | 2700 | 3140 | 75 | -25~+65 | 6.8 | F |
300 | 3P,380~440V | 2 | 380 | 50 | 250 | 0.45 | 2760/3000 | 2500 | 72 | -25~+65 | 4.7 | F |
300 | 3P,200~240/380~440V △/Y | 2 | 230/400 | 50/60 | 200/250 | 0.57/0.68/0.33/0.40 | 2250/2600 | 2600/2900 | 70/73 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 200/160/125 | 0.9/0.75/0.57 | 2400/2250/1820 | 2700/2350/1750 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 300/240/230 | 1.36/1.1/1.0 | 2750 | 2800/2600/2400 | 72 | -25~+50 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 300 | 1.38 | 2750 | 2800 | 72 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 160/140/125 | 0.75/0.63/0.57 | 2280/2160/1980 | 2350/2050/1750 | 64 | -25~+50 | 4.7 | F |
300 | 1P,220~240V | 2 | 230 | 50 | 250 | 1.1 | 3000 | 2530 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 230 | 50/60 | 180/230 | 0.8/1.1 | 2250/2550 | 2580/2860 | 70/72 | -25~+65 | 4.5 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 130 | 0.6 | 1950 | 2650 | 60 | -25~+70 | 4 | B |
300 | 3P,380~440V | 4 | 380 | 50 | 95 | 0.26 | 1950 | 1400 | 55 | -25~+60 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50 | 95 | 0.26 | 1950 | 1400 | 55 | -25~+65 | 4 | F |
300 | 1P,110~127V | 4 | 120 | 60 | 115 | 0.95 | 2000 | 1580 | 60 | -25~+65 | 3.2 | F |
300 | 1P,220~240V | 4 | 230 | 50/60 | 90/115 | 0.38/0.48 | 1900/2100 | 1370/1500 | 55/60 | -25~+65 | 3.2 | F |
300 | 3P,380~480V | 2 | 480 | 50/60 | 300/400 | 0.46/0.58 | 3260/3530 | 2500/3050 | 73 | -40~+80 | 0 | F |
300 | 1P,220~240V | 2 | 230 | 50 | 250 | 1.1 | 3000 | 2530 | 70 | -25~+65 | 6.8 | F |
300 | 1P,220~240V | 2 | 230 | 50/60 | 200/270 | 0.9/1.2 | 2300/2700 | 2750/3140 | 72/75 | -25~+65 | 6.8 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 250 | 1.1 | 2900 | 2530 | 70 | -25~+65 | 6.8 | F |
300 | 1P,220~240V | 2 | 230 | 50 | 250 | 1.1 | 3000 | 2530 | 70 | -25~+65 | 6.8 | F |
300 | 3P,380~440V | 4 | 380 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 6.1 | F |
300 | 3P,380~440V | 4 | 380 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 6.1 | F |
300 | 3P,360~440V | 2 | 400 | 50 | 290 | 0.53 | 3160 | 2600 | 79 | -25~+80 | 5.5 | F |
300 | 3P,380~440V | 2 | 380 | 50 | 250 | 0.45 | 3000 | 2500 | 72 | -25~+65 | 4.7 | F |
300 | 3P,380~440V | 2 | 380 | 50/60 | 200/250 | 0.33/0.40 | 2250/2600 | 2600/2900 | 70/73 | -25~+65 | 4.7 | F |
300 | 3P,200~240/380~440V △/Y | 2 | 230/400 | 50/60 | 200/250 | 0.57/0.68/0.33/0.40 | 2250/2600 | 2600/2900 | 70/73 | -25~+65 | 4.7 | F |
300 | 3P,380~440V | 2 | 380 | 50 | 165 | 0.33 | 1900 | 2550 | 77 | -25~+50 | 4.7 | F |
300 | 1P,220~240V | 2 | 230 | 50 | 250 | 1.1 | 3000 | 2530 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 230 | 50/60 | 200/270 | 0.9/1.2 | 2300/2700 | 2750/3140 | 72/75 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 160/90 | 0.75/0.41 | 2370/1400 | 2840/1720 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 160/90 | 0.75/0.41 | 2370/1400 | 2840/1720 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 160/90 | 0.75/0.41 | 2370/1400 | 2840/1720 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 150/105 | 0.72/0.47 | 2170/1400 | 2720/1780 | 70 | -25~+65 | 4.7 | F |
300 | 1P,220~240V | 2 | 220 | 50 | 130 | 0.6 | 1950 | 2650 | 60 | -25~+70 | 4 | B |
300 | 3P,200~240V | 4 | 220 | 60 | 125 | 0.45 | 2100 | 1550 | 60 | -25~+60 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50 | 95 | 0.26 | 1950 | 1400 | 55 | -25~+65 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 4 | F |
300 | 3P,380~440V | 4 | 400 | 50/60 | 95/120 | 0.26/0.24 | 1950/2200 | 1400/1600 | 55/60 | -25~+65 | 4 | F |
300 | 3P,380~440V | 4 | 380 | 50 | 95 | 0.26 | 1950 | 1400 | 55 | -25~+65 | 4 | F |
300 | 3P,380~480V | 4 | 400/460 | 50/60 | 95/120 | 0.26/0.24 | 1950/2150 | 1400/1600 | 55/60 | -25~+65 | 4 | F |
300 | 3P,200~240/380~440V △/Y | 2 | 230/400 | 50/60 | 200/250 | 0.57/0.69/0.33/0.40 | 2250/2600 | 2600/2900 | 70/73 | -25~+65 | 3.5 | F |
300 | 1P,110~127V | 4 | 120 | 60 | 115 | 0.95 | 2000 | 1580 | 60 | -25~+65 | 3.2 | B |
Base features
Supply:3P,380~440V, 50/60 Hz
Max airflow:1950/2150 m³/h (static pressure=0Pa)
Noise:55/60 dB(A)
Protection class:IP54
Insulation class:F
Bearings:maintenance-free ball bearings
Amb.temp.perm.:-25℃~+65℃
Structure features
Impeller material:cold rolled sheet steel
Direction:Blow
Blades count:5
Blade type:Integrated blade
Enclosure type:Flat and Wide Gap Guard Grille With wind tube
Net weight:6.1 kg
Motor features
Motor poles:4
Voltage:380 VAC
Power input:95/120 W
Current:0.26/0.24 A
Speed:1400/1600 r/min
View detail information
View photo
View performance
Specifications
1. Founded in 2001 to provide high-quality products and sourcing solutions at a competitive cost.
2. Manufacturing Facilities :Manufacturing plants located in multiple regions in China
3. Service locations: Fort Wayne, Indiana, USA(Responsible for after-sales service of products) Changzhou, Jiangsu, China
4. 2021 sales of $650 million In 2021, 1 million fans and 600,000 motors will be produced
5. The total number of employees is 268, including 20 technical teams and 26 sales team
Our Quality Control
1. Quality is everyone’s job → TQM -Total Quality Management
2. Higher quality means lower costs → TQC – Total Quality Cost Control.
3. Continuous Improvement → ISO9000 & Six Sigma Tools
4. Working with customer as a Team → Teamwork & Two Way Communications
Our customers